Type |
|
Input voltage |
Input current |
Output voltage |
Dimension R1xR2xH |
Mass g |
main application |
GYH-053-1 |
PS-12 |
2.65 |
≤18 |
Vs=5700
VMCP=825(ad)
Vc=200 |
11.5x21x23.5 |
≤35 |
For Gen.II wafer tube (Φ43) |
GYH-053-4 |
PS-52 |
2.65 |
≤18 |
Vs=5700
VMCP=825(ad)
Vc=200 |
10x17x11 |
≤20 |
For Gen.II wafer tube (Φ37) |
GYH-065-1 |
PS-42 |
2.65 |
≤32 |
Vs=6000
VMCP=825(ad)
Vc=3000
VR=2700 |
19.3x28.5x25.3 |
≤65 |
For 25mm Gen.II inverter tube |
GYH-044-2 |
|
2.65 |
≤32 |
Vs=4250
VMCP=825(ad)
VA=2800
VC=740 |
17.5x28.8x67.5 |
≤80 |
For 20/30 Gen.II inverter tube |
GYH-124-2 |
|
2.65 |
≤32 |
Vs=5700
VMCP=825(ad)
VS2=11000
VC=200 |
16.8x25.4x50 |
≤50 |
For 18/18 hybrid tube |
GYH-124-1 |
|
2.65 |
≤32 |
Vs=5700
VMCP=825(ad)
VS2=11000
VC=200 |
17.5x28.5x67.5 |
≤80 |
For 18/27 hybrid tube |
GYH-053-3 |
|
2.65 |
≤18 |
Vs=5700
VMCP=1600(Max.)
Vc=200 |
17x31x34 |
≤60 |
For double MCPs tube |
GYH-053-5 |
|
12 |
≤32 |
Vs=5700
VMCP=825(ad)
Vc=200
t
start=40ns
t
EGAC=5 |
LxWxH
40x25x13 |
≤35 |
For 18mm Gated tube |